The question was: who or what produces this error message:
transport error: incomplete
warning: /sbus@1f,0/SUNWsoc@0,0/SUNWplu@a0000000,78abb/sdd@1,2(sdd7)
The answer is:
The error message originates from a Sparc Storage Array
(SSA) - more precisely from the serial optical controller
device driver.
A case was opened due to the fact, that the system seems
to be still operational and it is not clear, whether a defect
on one of the disks, the cable or the controller itself is the reason
for the error message.
I wish to thank everyone out there for your fast answers.
I love this list.
By
Töns
-- _o) /\\ pgp fingerprint: 9B AC A5 CB C8 CC FC DC 25 B5 26 9A 5D 28 C0 3D _\_V