Sparc Ultra 1
(1) 167MHz CPU
512MB RAM
Solaris 2.5.1
Machine is continuously rebooting with the following
messages being displayed on the console:
"WARNING: THERMAL WARNING DETECTED"
Any hints?!
----------------------------------------------------------------------------
-----------------
Many thanks to the 30 respondents!!!
John Anderson Rahul Roy Benjamine Cline
Daniel Baker Bill Fenwick Iseminger
Sanjay Patel Michael Kohne Val Popa
Marc S. Gibian Foster@bial1.ucsd.edu Noel Fardy
Aaron Herskowitz Trevor Paquette Fred Crowner
Richard Kuehn job@piquin.uchicago.edu Wes Pfarner
Jarin Satterlee Glenn Satchell David Kinney
Bill Eric Olemans Lee Whitty
G Bhaskar Bismark Espinoza David Mitchell
The most complete answer - specifying the Sun SRDB number
follows;
----------------------------------------------------------------------------
------------
There is a problem with the factory installed cpu fans in the
desktop Ultras. The SRDB doc below points to the replacement
part needed. Sun should replace these under warranty.
The new fans have 7 fins, I think the old ones had 5?
The old fans had a high failure rate causing the machine
to shutdown.
SRDB ID: 14234
SYNOPSIS: cpu fan replacement for Ultra desktops
DETAIL DESCRIPTION:
The fan that is mounted above the processor on my ultra desktop system
is failing. Is it possible to swap just the fan or do I need to swap
out the entire motherboard?
SOLUTION SUMMARY:
Yes, it is possible to swap just the cpu fan.
Order part number (fru) 540-2761.
This is just the cpu cooling module fan.
To remove and replace the fan, you need a small Phillips screwdriver
and a static strap.
1- Halt and power off the system and remove the cover from the Ultra
desktop.
2- Locate the cpu fan (it is located in the back corner of the
motherboard
closest to the power supply).
3- Making sure that you are properly grounded with a static wrist
strap, unplug
the power connector of the cpu fan. It is connected at j0101
directly behind the UPA or SBUS connector (depending upon the
system model). You might need to to remove the SBUS or UPA card
that is installed to remove this cable.
4- After the cable is disconnected, loosen the two small philips head
screws that are located on opposite corners of the fan. You do not
have to pull them out at this point; it is fine if they are only
disengaged from their sockets.
5- Lift the bad fan off of the heat sink and remove the screws. Use
these
screws in the new fan.
6- Install new fan by reversing the process just executed.