SUMMARY Sparc 20 extra fans

From: Niall O Broin - Gray Wizard (nobroin@esoc.esa.de)
Date: Fri May 03 1996 - 02:38:22 CDT


Yesterday I asked

> We've just had Sun tell us that we need to add an extra fan into
> our SS20s. Is this just us or is Sun doing this world wide ?

The general consensus (from too many people to list) is that this is
a problem with cooling in SS20 esp. when there are two internal disks
and a CD-ROM drive. The extra fan sits in between (it's tiny) the hard
disks and the CD and is a standard item now so the retrofit is just up
to a certain serial number. I'm a little peeved that we're only hearing
about this now as some of you have had the fix done a year ago and we've
had soem SS20 disk failures which may well have been due to this. It is
world wide but nobody told this to the "engineer" Sun sent along who said
that it only applied to Germany - suddenly, Germany is the hottest country
in the world :-)

Thank you all and kindest regards,

Niall O Broin

UNIX Network Administrator, Stations and Communications Engineering Department
European Space Operations Centre nobroin@esoc.esa.de
Darmstadt, Germany Ph./Fax +49 6151 90 3619/2179